75A Guts G Trip Molded Case Circuit Breaker Specification

  • Rated Short Circuit Making Current
  • 15kA
  • Rated Short Circuit Breaking Current
  • 10kA
  • Phase
  • Three Phase
  • Mechanical Life
  • 10,000 operations
  • Breaking Capacity
  • 10kA
  • Product Type
  • Molded Case Circuit Breaker
  • Installation Options
  • Panel Mounting
  • Function
  • Circuit Protection
  • Poles Number
  • 3 Pole
  • Rated Voltage
  • 415V
  • Rated Current
  • 75A
  • Rated Frequency
  • 50/60Hz
  • Curves
  • Trip Curve C
  • Temperature Protection
  • Yes
  • Weight
  • Approx. 1.5 kg
  • Color
  • White
  • Operating Temperature
  • -5 to 40C
  • Toggle operation
  • Manual lever
  • Trip Type
  • Thermal-Magnetic
  • Wire Connection
  • Screw Terminals
  • Mounting Position
  • Vertical or Horizontal
  • Compact construction
  • Yes
 

75A Guts G Trip Molded Case Circuit Breaker Trade Information

  • Minimum Order Quantity
  • 10 Pieces
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

75A Guts G Trip Molded Case Circuit Breaker About



Pick Yours today - the 75A Guts G Trip Molded Case Circuit Breaker is engineered for unassailable circuit protection. With soaring performance levels, remarked reliability, and a compact form, it is built for versatile installations. This robust breaker features a manual toggle operation, thermal-magnetic trip, and C trip curve, with a remarkable 10,000 mechanical life cycles. Operate efficiently between -5C to 40C, and secure your panels with reduced downtime. Suitable for three-phase networks at 415V and 75A, get it now from the leading manufacturer and supplier in India.

Diverse Applications & Usage of the 75A Guts G Trip Circuit Breaker

Engineered for flexibility, the 75A Guts G Trip Molded Case Circuit Breaker is used across commercial, industrial, and large residential settings. Its remarkable thermal-magnetic functionality and robust build make it ideal for panel board integration, motor protection, and main distribution boards. Commonly used as the primary isolator or circuit protection device, it ensures unassailable safety for critical electrical infrastructure. Installable on both horizontal and vertical mounts, this breaker adapts seamlessly to varied system requirements.


Export Market Reach & Shipping Excellence

The 75A Guts G Trip Circuit Breaker boasts a soaring reputation both domestically and abroad. Exported to a diverse clientele, domestic mar deliveries are prioritized alongside international drop-off protocols. Each unit is securely packaged for safe goods transport, ensuring optimal condition upon arrival. Payment processes are streamlined, supporting multiple terms to suit customer convenience. Trust in prompt turnaround and expert logistics support for hassle-free procurement and installation, locally and for export markets.


FAQ's of 75A Guts G Trip Molded Case Circuit Breaker:


Q: How is the 75A Guts G Trip Molded Case Circuit Breaker installed?

A: Installation is simple with panel mounting options, and the breaker can be positioned either vertically or horizontally using screw terminals for wire connections.

Q: What makes the 75A Guts G Trip Circuit Breaker suitable for various applications?

A: Its thermal-magnetic trip type, robust construction, and three-phase compatibility allow it to protect circuits in industrial, commercial, and residential settings.

Q: Where can I use this molded case circuit breaker?

A: It can be used in main distribution panels, motor protection circuits, and control boards across multiple sectors for reliable circuit protection.

Q: What benefit does the C trip curve offer?

A: The C trip curve ensures fast response to overloads and short circuits, providing optimal protection for sensitive and critical equipment.

Q: When should the circuit breaker be replaced?

A: After reaching its mechanical life of 10,000 operations or if signs of mechanical wear or malfunction are observed, replacement is recommended to maintain safety and performance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Molded Case Circuit Breakers Category

63A Guts G Trip Molded Case Circuit Breaker

63A Guts G Trip Molded Case Circuit Breaker

Minimum Order Quantity : 10 Pieces

Rated Voltage : 690V

Rated Current : 63A

Mechanical Life : 10,000 operations (typical)

Installation Options : Panel Mounting

Breaking Capacity : 16kA

100A Guts G Trip Molded Case Circuit Breaker

100A Guts G Trip Molded Case Circuit Breaker

Minimum Order Quantity : 10 Pieces

Rated Voltage : 415V

Rated Current : 100A

Mechanical Life : 10,000 operations

Installation Options : Panel Mounting

Breaking Capacity : 16kA

125A Guts G Trip Molded Case Circuit Breaker

125A Guts G Trip Molded Case Circuit Breaker

Minimum Order Quantity : 10 Pieces

Rated Voltage : 415V

Rated Current : 125A

Mechanical Life : 10,000 operations

Installation Options : Panel mount / DIN rail mount

Breaking Capacity : 10kA